|
Instrumentation & Control Equipments
|
Suppliers Directory
|
MANAS MICROSYSTEMS PVT LTD
| Address : |
EL-54 ELECTRONIC ZONE, MIDC BHOSARI |
Telephone : |
020-7127044/457127858 |
Fax : |
91-20-7127045 |
Send : |
On-Line Trade Inquiry |
|
Products |
ELECTROMAGNETIC FLOW METER FULL BORE TYPE - IDEAL FOR LIQUIDS WITH LOW CONDUCTIVITIES, VIZ, ABOVE 51 SIEMENS/CM. THE METHOD OF FLOW MEASUREMENT IS BASED ON FARADAY'S LAW OF ELECTROMAGNETIC INDUCTION. IN CASE OF THE FLOW METER, THE FLOWING MEDIA ACTS AS A CONDUCTOR AND CUTS THE MAGNETIC FIELD GENERATED IN THE FLOW TUBE WITH THE HELP OF A COIL. THE SIGNAL IS SENSED AND AMPLIFIED IN THE TRANSMITTER SECTION TO GIVE AN OUTPUT SIGNAL OF 4 TO 20 MA PROPORTIONAL TO THE FLOW RATE OF THE FLOWING MEDIA. ADDITIONALLY, FLOW RATE DISPLAY AS WELL AS A COUNTER FOR FLOW TOTALISATION CAN BE PROVIDED ON DEMAND. THE FLOW MEATUREMENT IS INDEPENDENT OF VELOCITY PROFILE, DENSITY, VISCOSITY, PRESSURE, AND TEMPERATURE AND SOLID IMPURITIES. ALSO, THERE IS NO PRESSURE DROP ACROSS THE FLOW METER AS THERE IS NO OBSTRUCTION IN THE PATH OF FLOW. ACCURACY OFFERED BY THE FLOW METER IS +0.5% OF ACTUAL FLOWO FOR VELOCITIES AS LOW AS 0.1 M/S AND FOR LINE SIZES RANGING FROM DN 10 TO DN 300. MAJOR APPLICATIONS ARE SLURRIES, PAPER-PULP, EFFLUENTS, MOLASSES AS WELL AS CORROSIVE LIQUIDS THAT ARE DIFFICULT TO MEASURE WITH CONVENTIONAL METHODS OF FLOW MEASUREMENT LIKE ORIFICE METER/VORTEX/MASS FLOW METERS.
|
MAGNETIC FLOW METER - MANAS DEVELOPED ELECTROMAGNETIC SROAT-1000 IS A NEAR IDEAL FLOW METER SUITABLE FOR WIDE RANGE OF LIQUID FLOW MESUREMENTS EVEN WITH VERY LOW CONDUCTIVITES. IT PROVIDES NO RESISTANCE TO FLOW HENCE THE PRESSURE DROP IS ALMOST NEGLIGIBLE. THE MEASUREMENT BEING BASED ON FARADAY'S LAW OF ELECTROMAGNETIC INDUCTION IS INDEPENDENT OF VISCOSITY DENSITY, PRESSURE AND TEMPRATURE OF FLOWING MEDIUM. THIS IS NOT SOLID IMPURITIES AS LONG AS THE MM CONDUCTIVITY OF 5 PS/CM IS AVAILABLE. IT THIS IS THE VOLUMETRIC FLOW MEASUREMENT DIFFERNT OF CONSTRUCTION FOR METER LINING AND ELECTRODES ARE AVAILABLE OPTIONALLY TO COVER MAJORITY OF CORROSIVE LIQUIDS. THE TECHNIQUE IS CALLED AS PULSED DC IS USED WHICH OFFERS VERY HIGH ZERO STABILITY AND ACCURACY OF MEASUREMENT. THE DARD CURRENT OUTPUT OF 4-20 MA DC IS GIVEN WHICH IS LINEARLY PROPORTIONAL TO VOLUMETRIC FLOW RATE AND ADDITIONAL FREQUENCY OUTPUT IS ALSO PROVIDED. ITS ADVANTAGES ARE EXCELLENT LONG TERM ZERO STABILITY; MEASUREMENT INDEPENDENT OF VELOCITY PROFILE ACROSS THE DIAMETER OF THE PIPE-LINE; MEASUREMENT RESULTS INDEPENDENT OF DENSITY, VISCOSITY, PRESSURE, TEMPERATURE, SOLID-IMPURITIES AND CONDUCTIVITY VARIATIONS (ABOVE 5TH SIEMENS) AND TO ADDITIONAL PRESSURE DROP ACROSS THE METER WHICH RELIEVES THE PROCESS DESIGNER WHILE SIZING HIS PUMPLING REQUIREMENTS.
|
|
|
View More Supplier Pages
Page(s) : 1 •
2 •
3 •
4 •
5 •
| |
|
|
|